Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mem. Inst. Oswaldo Cruz ; 108(2): 255-256, abr. 2013. tab
Artigo em Inglês | LILACS | ID: lil-670410

RESUMO

Rabies is a neurotropic disease that is often lethal. The early diagnosis of rabies infection is important and requires methods that allow for the isolation of the virus from animals and humans. The present study compared a modified shell vial (MSV) procedure using 24-well tissue culture plates with the mouse inoculation test (MIT), which is considered the gold standard for rabies virus isolation. Thirty brain samples (25 positive and 5 negative by the fluorescent antibody test) obtained from different animal species at the National Institute of Hygiene Rafael Rangel in Caracas, Venezuela, were studied by the MIT and MSV assays. Nine samples (36%) were positive at 24 h, 10 (40%) were positive at 48 h and six (24%) were positive at 72 h by the MSV assay. With the MIT assay, 76% were positive at six days post inoculation and 12% were positive at 12 and 18 days post inoculation. One sample that was negative according to the MSV assay was positive with MIT on the 12th day. The MSV procedure exhibited a sensitivity of 96.2%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value 80%. This procedure allowed for rapid rabies virus detection. MIT can be employed as an alternative method in laboratories without tissue culture facilities.


Assuntos
Animais , Gatos , Bovinos , Cães , Humanos , Camundongos , Vírus da Raiva/isolamento & purificação , Raiva/diagnóstico , Anticorpos Antivirais , Quirópteros , Imunofluorescência , Cabras , Vírus da Raiva/imunologia , Sensibilidade e Especificidade , Fatores de Tempo , Técnicas de Cultura de Tecidos
2.
Rev. cuba. med. trop ; 51(2): 130-132, May-Aug. 1999.
Artigo em Espanhol | LILACS | ID: lil-333522

RESUMO

DAVIH AC p24 kit for detecting anti p24 antibodies of HIV-1, worked out by the National Laboratory of Reference of AIDS (Labor-1, Cuba) is assessed and results are compared to those of the Western Blot technique (DAVIH-Blot, Labor-1, Cuba). 191 samples from HIV positive patients at various stages of the disease were analyzed. 96 sensitivity; 100 specificity and 96.3 coincidence were found in both techniques. The anti p-24 ELISA-DAVIH system is a good alternative for the follow-up of HIV positive patients.


Assuntos
Humanos , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática , /imunologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...